As a 15+ year user of DRC's SPIDR gauge, I can attest to its utility. The SPIDR has given the operator a low-cost alternative to downhole gauges, especially when running an extended well test or back-to-back tests on ... - Ralph R. Roesler
We have recently been approached by several operators
around the world who are curious about non-traditional applications for our
SPIDR hardware.For many years the SPIDR
has been used to collect high quality surface pressure data.This has always been the primary purpose of
our tool.Occasionally the SPIDR is also
used to gather additional data on wells while it is at the wellsite gathering
tubing pressure data.Some of these additional
data sources include liquid injection rates, casing pressure, temperature, and gas
flow rate.The ability to accurately
record gas flow rates is the most frequently requested additional measurement.
We have seen that in many locations it is difficult to
get an accurate measurement of flow rates.This can be due to failure of existing hardware or an inadequacy in the
hardware that is installed.The SPIDR
can be used as a simple and portable tool for very accurately measuring flow
rate information on these wells.Quite
often this information will be used as an input into our overall SPIDR Well
Testing System to allow the most accurate conversion of flowing surface
wellhead pressures to bottomhole conditions.
The SPIDR can simultaneously record up to 3 data streams,
via two external transducers and our high resolution/high frequency internal
pressure transducer.One of the two
external sources can be a differential pressure cell (d/p cell). Installing a d/p cell across an orifice plate,
allows gas flow rate to be calculated using the following formula.
FLOW = K x (d/p x P)^0.5
In
the above formula K is a coefficient which considers ten different correction
factors including gas composition, gas density and temperature, line I.D.,
orifice I.D. and non-ideal gas behavior. The term d/p is the pressure drop
across the orifice plate and P is the line pressure. For many applications,
assumptions can be made about some of the correction factors without
sacrificing the accuracy required for that application. The SPIDR system
may be used in three different modes for flow measurements across an orifice
plate. Each of these three modes is described below from least accurate to most
accurate.
1. GAS FLOW APPROXIMATION:
This
method assumes that the line pressure and flowing gas temperature are fairly
constant. A SPIDR is installed at the well-head and a d/p cell is
installed across the orifice plate taps. The formula for flow now includes
constant line pressure and temperature values in the coefficient as follows:
K' = K x P^0.5FLOW = K' x (d/p)^0.5
2. SPIDR
OR EXTERNAL TRANSDUCER USED TO MONITOR LINE PRESSURE:
This
method uses the SPIDR's internal transducer or an external pressure
transducer to measure the line pressure on the high-pressure side of the
orifice plate and a d/p cell connected across the orifice plate taps.Here line temperature is still assumed to be
constant. By measuring changes in the line pressure, a more accurate value can
be obtained for the flow rate.
3.
HIGH PRECISION METHOD:
This
method utilizes a d/p cell connected across the orifice plate, the SPIDR's
internal transducer to monitor the line pressure and a temperature probe to
monitor the flowing gas temperature. This is the most accurate method to
monitor flow rates.
Our
free Flowcom software (available at www.spidr.com),
that is used to interface with the SPIDR and download data from the SPIDR, can
also be used to calculate not only instantaneous rates but also cumulative
production.An example plot of pressure
and flow data gathered by the SPIDR during the first 27 days of a well’s
production is shown below.Here the blue line represents wellhead
pressure the green line is instantaneous gas flow rate and the red line is
cummulative production.
The SPIDRs ability to record multiple data streams and at once and incorporate all the data in an easy to use format makes it an excellent tool for measuring flow rates. The SPIDR can record up to 2.5 million samples in the standard mode (option 1) and up to 1.3 million samples in high precision mode (options 2 and 3). The portable nature and large memory capacity of the SPIDR makes it especially useful for gathering flow rate information at remote locations where it can be difficult to obtain more conventional flow monitoring equipment. Installing a d/p cell across an orifice plate,
allows gas flow rate to be calculated using the following formula.