Newsletter Sign-Up
Submit Your Email:
Testimonials
In my business I spend a lot of time analyzing pressure data from fracture injection tests using NuTechís NuFIT process. The results of this analysis provide a measure of the permeability and pore pressure that is needed to ...
- Corby Goodman

SPIDR Installation

Install the supplied DRC 'Tee' upstream of the choke. The most common installation position is between the needle valve and pressure gauge on the crown of the well.

Connect one end of the capillary tubing to the DRC 'Tee'. Connect the other end of the capillary tube to the pressure port on the SPIDR . Do not kink the capillary tube or bend the capillary tube close to its end. Open the needle valve and check for leaks. Note that flow does not need to be interrupted in order to install the SPIDR system.

Spidr Installation 

Are instructions included with the SPIDR showing how to install it?

Yes, included in the box is a detailed schematic showing how to connect the SPIDR, you can also download the instructions on installing the SPIDR here: SPIDR Installation Sheet

 


Home  About DRC  The SPIDR  Analysis Tools  Literature  Contact Us  News  Careers 

Site Map  Disclaimer 

DRC - Data Retrieval Corporation

13231 Champions Forest Drive, Suite 401,
Houston, TX 77069
Phone 281-444-5398 • Fax 281-444-5397

Questions, comments or suggestions? Contact Us
(c) 2010 DRC - Data Retrieval Corporation

Site Admin

Site by Paradigm Web Design

Site Ensemble CMS Copyright © 2010 Paradigm New Media, LLC. All rights reserved.