SPIDR Installation

Back to Tutorials

Install the supplied DRC 'Tee' upstream of the choke. The most common installation position is between the needle valve and pressure gauge on the crown of the well.

Connect one end of the capillary tubing to the DRC 'Tee'. Connect the other end of the capillary tube to the pressure port on the SPIDR . Do not kink the capillary tube or bend the capillary tube close to its end. Open the needle valve and check for leaks. Note that flow does not need to be interrupted in order to install the SPIDR system.

Spidr Installation 

Are instructions included with the SPIDR showing how to install it?

Yes, included in the box is a detailed schematic showing how to connect the SPIDR, you can also download the instructions on installing the SPIDR here: SPIDR Installation Sheet

 

 